Category: Railroad VOM Test Sets
Specifications | Model 2000 | Model 2001 | Model 2002 | Model 2003 |
DC Voltage | 0.6V, 3V, 15V, 60V, 300V | 0.6V, 3V, 15V, 60V, 300V | 0.6V, 3V, 15V, 60V, 300V | 0.6V, 3V, 15V, 60V, 300V |
DCV Accuracy | ±1.5% FS | ±1.5% FS | ±1.5% FS | ±1.5% FS |
DC Milliamps | 16mA, 60mA, 300mA | 16mA, 60mA, 300mA | 16mA, 60mA, 300mA | 16mA, 60mA, 300mA |
DC mA Accuracy | ±1.5% FS | ±1.5% FS | ±1.5% FS | ±1.5% FS |
DC Amps | 1.5A, 6A, 30A | 1.5A, 6A, 30A | 1.5A, 6A, 30A | 1.5A, 6A, 30A |
DCA Accuracy | ±1.5% FS | ±1.5% FS | ±1.5% FS | ±1.5% FS |
AC Voltage | 1.5V, 3V, 15V, 150V, 300V, 600V | 1.5V, 3V, 15V, 150V, 300V, 600V | 1.5V, 3V, 15V, 150V, 300V, 600V | 1.5V, 3V, 15V, 150V, 300V, 600V |
ACV Accuracy | ±3.0% FS | ±3.0% FS | ±3.0% FS | ±3.0% FS |
AC Amps | 1.5A, 6A, 30A | 1.5A, 6A, 30A | 1.5A, 6A, 30A | 1.5A, 6A, 30A |
ACA Accuracy | ±3.0% FS | ±3.0% FS | ±3.0% FS | ±3.0% FS |
Cab Filter Response (All AC ranges) |
60Hz: — 100Hz: — 200Hz: — 250Hz: — |
60Hz: — 100Hz: 92 to 100Hz 200Hz: — 250Hz: 245 to 255Hz |
60Hz: — 100Hz: 92 to 100Hz 200Hz: 196 to 204Hz 250Hz: — |
60Hz: 57 to 63Hz 100Hz: 92 to 100Hz 200Hz: — 250Hz: — |
Code Functions (All AC and DC Ranges) |
On Time: 3% to 100% (±3% FS) Rate: 30 to 500CPM (±3% FS) Peak Hold: Ö Peak Follow: Ö |
On Time: 3% to 100% (±3% FS) Rate: 30 to 500CPM (±3% FS) Peak Hold: Ö Peak Follow: Ö |
On Time: 3% to 100% (±3% FS) Rate: 30 to 500CPM (±3% FS) Peak Hold: Ö Peak Follow: Ö |
On Time: 3% to 100% (±3% FS) Rate: 30 to 500CPM (±3% FS) Peak Hold: Ö Peak Follow: Ö |
Volt Senese Mode | 15V AC or DC (±20%) | 15V AC or DC (±20%) | 15V AC or DC (±20%) | 15V AC or DC (±20%) |
Resistance |
Range: R x 1 and R x 100 Center Scale: 5 and 500 ohms Accuracy: ±2% of scale length |
Range: R x 1 and R x 100 Center Scale: 5 and 500 ohms Accuracy: ±2% of scale length |
Range: R x 1 and R x 100 Center Scale: 5 and 500 ohms Accuracy: ±2% of scale length |
Range: R x 1 and R x 100 Center Scale: 5 and 500 ohms Accuracy: ±2% of scale length |
Dry Contact |
Allowable Resistance: 0 to 100 ohms Test Voltage: 7.5 to 15VDC Test Current: less than 1mA |
Allowable Resistance: 0 to 100 ohms Test Voltage: 7.5 to 15VDC Test Current: less than 1mA |
Allowable Resistance: 0 to 100 ohms Test Voltage: 7.5 to 15VDC Test Current: less than 1mA |
Allowable Resistance: 0 to 100 ohms Test Voltage: 7.5 to 15VDC Test Current: less than 1mA |
Power | (2) 9V; (1) 1.5V D cell | |||
Dimensions | 5 x 6.5 x 3.2'' (127 x 165.1 x 81.3mm) | 5 x 6.5 x 3.2'' (127 x 165.1 x 81.3mm) | 5 x 6.5 x 3.2'' (127 x 165.1 x 81.3mm) | 5 x 6.5 x 3.2'' (127 x 165.1 x 81.3mm) |
Weight | 4.75 lbs (2.15kg) with case and leads | 4.75 lbs (2.15kg) with case and leads | 4.75 lbs (2.15kg) with case and leads | 4.75 lbs (2.15kg) with case and leads |
Please Leave Your Product Enquiry Here. We will Get Back To You Soon.