SBS-H2-DoD HYDROGEN GAS DETECTOR


Quantity: Out Of Stock

Category: Gas Detection

Quick Overview:

Hydrogen Sensor and Monitoring System


Benefits

  • Protects life, property and company profits
  • Ideal for remote locations
  • Fail safe mode in event of loss of power
  • Up to three (3) sensors can be installed to main control to meet space coverage requirements

Features

  • Universal power inputs: 110/220 Vac and/or 12–48 Vdc input
  • Strobe light for visual alerts
  • Sensor status indicator LEDs on the main control
  • Modular design for optimal placement of sensor(s)
  • NRTL/C Certified: UL Std. No 61010-1 & CAN/CSA-C22.2 No. 61010-1-12
  • UFC 3-520-05, January 2020

Installation

  • Wall or 2-gang junction box mountable
  • Mechanical relays are easily accessible:
    • Warning 0.5 % relay, 15 A @ 120 Vac; 10 A @ 277 Vac; 10 A @ 28 Vdc
    • Alarm 1% relay, 0.5 A resistive @ 28 Vdc, 0.5 A @ 125 Vac
  • Redundant power supply capability; dual AC and/or DC power supply connections (DC power supply will operate as backup power source)
  • Indicator LEDs can be tested by pushing the red “TEST” button
  • Sensors can be tested in the field with the P/N H2-TESTKIT

Detector can operate exhaust fans and building alarms / SCADA systems:

battery hydrogen sensor diagram

Warning Settings: Should the concentration of hydrogen gas in the air surrounding the sensor reach 0.5% by volume, the “0.5% Warning” yellow LED will light up on the main control of the unit. In addition, the 0.5% internal relay will energize and can be used to activate an external exhaust fan or a building management/alarm system (via SCADA Modbus).

Alarm Settings: Should the hydrogen gas concentration reach 1% by volume, the “1% Alarm” red LED will light up, the strobe will flash and an audible alarm will sound. In addition, the 1% internal relay will energize and can be used to activate a building management/alarm system (via SCADA/Modbus).

SBS-H2-DoD Includes

  • Main unit
  • Hydrogen sensor
  • 25 ft. cable
Tag: #SBS-H2-DoD 

Share: Messenger


Hydrogen Sensor and Monitoring System


Benefits

  • Protects life, property and company profits
  • Ideal for remote locations
  • Fail safe mode in event of loss of power
  • Up to three (3) sensors can be installed to main control to meet space coverage requirements

Features

  • Universal power inputs: 110/220 Vac and/or 12–48 Vdc input
  • Strobe light for visual alerts
  • Sensor status indicator LEDs on the main control
  • Modular design for optimal placement of sensor(s)
  • NRTL/C Certified: UL Std. No 61010-1 & CAN/CSA-C22.2 No. 61010-1-12
  • UFC 3-520-05, January 2020

Installation

  • Wall or 2-gang junction box mountable
  • Mechanical relays are easily accessible:
    • Warning 0.5 % relay, 15 A @ 120 Vac; 10 A @ 277 Vac; 10 A @ 28 Vdc
    • Alarm 1% relay, 0.5 A resistive @ 28 Vdc, 0.5 A @ 125 Vac
  • Redundant power supply capability; dual AC and/or DC power supply connections (DC power supply will operate as backup power source)
  • Indicator LEDs can be tested by pushing the red “TEST” button
  • Sensors can be tested in the field with the P/N H2-TESTKIT

Detector can operate exhaust fans and building alarms / SCADA systems:

battery hydrogen sensor diagram

Warning Settings: Should the concentration of hydrogen gas in the air surrounding the sensor reach 0.5% by volume, the “0.5% Warning” yellow LED will light up on the main control of the unit. In addition, the 0.5% internal relay will energize and can be used to activate an external exhaust fan or a building management/alarm system (via SCADA Modbus).

Alarm Settings: Should the hydrogen gas concentration reach 1% by volume, the “1% Alarm” red LED will light up, the strobe will flash and an audible alarm will sound. In addition, the 1% internal relay will energize and can be used to activate a building management/alarm system (via SCADA/Modbus).

SBS-H2-DoD Includes

  • Main unit
  • Hydrogen sensor
  • 25 ft. cable

Specification

Power Supply(s) 110/220 Vac, 50/60 Hz and/or
12–48 Vdc (9–58 Vdc operating voltage)
12.5% LEL (Lower Explosive Limit) Dry contacts rated 10A/250 Vac
25% LEL (Lower Explosive Limit) Dry contacts rated .5A/28 Vdc
Dimensions 4.7'' L x 4.7'' W x 1.2'' D (main control)


Sorry, Currently No Video Uploaded.

SBS-H2-DoD HYDROGEN GAS DETECTOR


Please Leave Your Product Enquiry Here. We will Get Back To You Soon.

Product Specifications

  • Product SKU : -
  • Weight (GRAM) : -
  • Dimension : -